Transformer neutral grounding protection devise

Transformer neutral grounding protection devise
Product Detailed
Related Categories:Other Electrical Equipment
1.system voltage:220kV 2.Provide over-voltage protection by direct ground or not 3.modular design

1.The grounding protection device is applicable to 110kV, 220kV or 330kV power transformer circuits in order to realize the conversion of earthing method.

2.Structure

(1)Disconnecting Switch

(2)Zinc-oxide Surge Arrestor

(3)Rod Gap

(4)Current Transformer

(5)Mounting Brackets

3.Installation: The complete device is supported on the cement posts or steel supports which is usually provided by the tender. W e can also supply the steel supports as an accessory.

4.Site condition:

(1)Ambient temperature: -50°C-70°C

(2)Altitude: less than 4500m.

(3)Frequency :50Hz or 60Hz

(4)Installation: Indoor or outdoor

5.Typical products parameters table

Transformer system Nominal Voltage

220kV

Insulation level

Light impulse withstand voltage

400 kV

Power frequency withstand voltage

95 kV

Rod Gap

Type

THT-TNP-220

Descriptions

Electrode bar with hemispheric ends

The adjustable range

250-360mm

Current Transformer(Used for protecting rod gap )

Type

THT-LJ80

Model

Epoxy-resin filled totallyclosed type

Rated primary current

100A 150A 300A 400A 500A 600A

Rated secondary current

1A/5A

Accurate combination and ratings

10P5/10P5 15VA/15VA

Disconnecting Switch

Type

GW13-126

Rated voltage

126Kv

Rated current

630A/1250A

Operating mechanism

CS17 type manual operating mechanism,CJ6 type motor-driven operating mechanism

Surge Arrester

Type

Y1.5W-144/320

Nominal discharging current

1.5kA

Rated voltage

144kV

Continuous operating voltage

116kV

Lighting impulse residual voltage

320kV

Counter/Monitor

JS8 type surge arrester counter/JCQ3 type surge arrester monitor

 Note: the above table is relating to the general parameters for your consideration, please let us know if you have any special requirements.

6.Choosing the type

Type

Voltage level

Configuration solutions

THT-TNP-110/220/330/Ⅰ

110kV/220kV/330kV

Protection Rod Gap

THT-TNP-110/220/330/Ⅱ

110kV/220kV/330kV

Rod Gap and Disconnecting Switch

THT-TNP-110/220/330/Ⅲ

110kV/220kV/330kV

Rod Gap ,Disconnecting Switch and arrester

THT-TNP-110/220/IV

110 kV

Rod Gap ,Disconnecting Switch and arrester (compact)

Transformer neutral grounding protection devise