transformer neutral earthing resistors
1.About us:
Baoding Tianwei Hengtong Electric company is a domestic professional manufacture of power system neutral grounding equipments and complete implements ISO9001 quality management system. We have a excellent sales performance all over the world and have been exported to more than 40 countries. TWHT offers a complete range of products for the necessary neutral-point connections
2.General introduction
THT-ZT neutral grounding resistor cabinet (NGR or NER) are employed in medium-voltage AC distribution networks to limit the current that would flow through the neutral point of a transformer in the event of an earth fault. It connected between the neutral point of the transformer and the earth.
3.Options include:
1)Earthing transformer or grounding transformer
When the transformer windings adopt delta connection and a Zigzag connecting, Grounding transformer needs to be separately installed, the THT-ZT-type neutral grounding resistor cabinet can be matched.
2)Intelligent control units.
It would not only monitor the earth fault and temperature of unbalanced current and resistors, but also record the current value, time, NGR temperature changes and grounding frequency. At the same time, it will transmit the above information to the main control room.
4.specifications:
Ambient temperature: -40C~60°C
Altitude: less than 4000m
Relative humidity: less than 95% (25°C)
Codes and standards: IEEE-32 ,DL/T 780-2001
Rated frequency: 50/60HZ
Location: outdoor/indoor
Enclosure: aluminum-zinc plates, stainless steel plates or cold-rolled steel plates according to your requirements.
Resistor material: stainless steel
Degree of protection: design as required
When the transformer windings adopt delta connection and a Zigzag connecting grounding transformer needs to be separately installed, the THT-ZT-type neutral grounding resistor cabinet can be matched
.
3.Regular Technical Particulars for reference
Type | Rated Voltage(KV) | Short Time Current(A) | Flow Time (S) | Resistance Value(Ω) | Outer Dimensions |
THT-ZT-6/34.64 | 6 | 100 | 10 | 34.64 | 1200x1200x1870 |
THT-ZT-6/17.32 | 6 | 200 | 10 | 17.32 | 1200x1200x1870 |
THT-ZT-6/8.66 | 6 | 400 | 10 | 8.66 | 1200x1200x1870 |
THT-ZT-6/5.77 | 6 | 600 | 10 | 5.77 | 1200x1200x1870 |
THT-ZT-10/14.43 | 10 | 400 | 10 | 14.43 | 1200x1200x1870 |
THT-ZT-10/9.62 | 10 | 600 | 10 | 9.62 | 1200x1200x1870 |
THT-ZT-10/7.22 | 10 | 800 | 10 | 7.22 | 1200x1200x1870 |
THT-ZT-10/5.77 | 10 | 1000 | 10 | 5.77 | 1200x1200x1870 |
THT-ZT-35/20.21 | 35 | 1000 | 10 | 20.21 | 2760x2600x2000 |
THT-ZT-35/10.10 | 35 | 2000 | 10 | 10.10 | 2760x2600x2000 |
( function(){ var aBigImageSrc = [ 'http://i00.i.aliimg.com/photo/v2/607500908_1/transformer_neutral_earthing_resistors.jpg' , 'http://i00.i.aliimg.com/photo/v2/607500908_2/transformer_neutral_earthing_resistors.jpg' , 'http://i00.i.aliimg.com/photo/v2/607500908_3/transformer_neutral_earthing_resistors.jpg' ]; var oProductShow = new AE.run.minisite.productShow(); oProductShow.init( { 'aImgSrc': aBigImageSrc } ); } )(); transformer neutral earthing resistors